Ion Air Nuzzle

Ionizing Air Nuzzle is designed to neutralize static charge eliminate contaminates. 
It features a self contained HV power unit, foot pedal, and adjustable neck. As with all Botron ionizers, it is equipped with auto ion balance and abnormal HV alarm system.

The Ionizing Air Nuzzle is the perfect solution for those who need pin point ionization of static sensitive components. While eliminating static charge it also removes any charged particles or debris that can collect on components. The adjustable neck provides the freedom of use for operators as well as precision ionization.




Notes:
  • Light weight and compact design.
  • Auto ion balance
  • Abnormal HV alarm
  • Adjustable neck
  • Uses both compressed air and nitrogen
  • LED indicators
  • Built in HV power supply
  • Alloy discharge needle





















Mounting:


The compact design of the ion snake requires minimal room on the work surface. All ionizing snakes should be placed within the specified range for proper ionization of static sensitive components.

Applications:


The ionizing snake is designed neutralize electrostatic charge in personal bench top environments, sensitive materials assembly, packaging, clean room and laboratories. The versatile adjustable neck of the ion snake makes this an exceptional unit for work stations where space is limited and for those tricky and tight areas only a precision ionizer gun or snake can provide.


Performance:
Ion balance +/- 10v
Positive decay times range from (sec) 0.5 at 3 kgf/cm2 to 0.2 at 6 kgf/cm2
Negative decay times range from (sec) 0.5 at 3 kgf/cm2 to 0.2 at 6 kgf/cm2i
*All results are based according to EOS/ESD-STM 3.1-2000.
*Results may vary based on test conditions.
Detailed Info:
  • Power supply
  • Output HV
  • Air pressure range
  • Air pressure range (filter)
  • Air input
  • Ozone Density
  • Indicators
  • Controls
  • Emitter
  • Air line connector
  • Weight
  • AC100 – 240V 50/60Hz
  • AC2200V
  • 2 – 7 kgf/cm2
  • 1 – 7 kgf/cm2
  • Compressed air or N2 without oil and water
  • <.01ppm
  • Green LED, Red LED
  • On/Off button
  • Alloy
  • ¼ NPT
  • 1 lb
Trouble shooting:
The abnormal HV alarm and the red light indicator will alarm if the following problems occur.
  • Low output HV.
  • Short circuit.
  • Abnormal HV discharge.
  • Wet air flow.
  • Rapid turning on and off of photoelectric switch

Contact:
Tecmer,Lda 
Tel:+351 932308640 /+351 252317314
Email:geral@tecmer.pt
www.tecmer.pt



Comentários